Fluid Chillers, Inc
Fluid Chillers, Inc

Air Cooled Chillers offered by General Air Products range from fractional (0.25) up to 60 tons in cooling capacity. Our industrial air chillers are available in a variety of configurations – packaged with a pump and tank, portable, stationary, without pumps or tanks and split units. air cooled chillers that are easy to install, easy to repair and will give you significant savings. The air cooled chiller is compact in size allowing for easy installation in places where space is severely limited. Along with cost efficiency in purchase and installation, Aqua Series chillers are also more affordable to operate. They are highly efficient, with full-load energy efficiency ratios up to 10.9 and integrated part-load value ratings as high as 17.9. The key to Aqua Series chillers’ great operating performance is the use of highly efficient rotary scroll and screw compressors. These compressors use patented sealing techniques, allowing for high volumetric efficiency and low frictional losses.

Condenser coils use a V configuration to optimize heat rejection and footprint. Most Multistack modular systems comply with ASHRAE 15 and CSA B52 standards, which means you can do without auxiliary ventilation, monitoring and SCBA equipment. Not to mention an operational advantage when it comes to obtaining LEED certification. If your current chiller shows signs of aging and you are considering replacement, we are confident that you will find using our screw chillers will help you a lot with production efficiency and cost reduction. 8.2.1Adjust the cooling system flow valve carefully , to make system water flow be 90% water flow required by the nameplate on the unit. 1)Air-cooled condenser of this screw chiller with upside-down M shape layout to improve space using ratio, heat exchange area of air-cooled condenser and to reduce the unit overall size. 2)High automatic management with complete features to realize unit start-up and shut down, timing control, water pump control, malfunction alarm and self-diagnosis features. 2)A brand condensing axial fan is used in the screw chiller unit. Air-cooled screw chiller having integrity structure saves the cooling tower and reduces construction investment. Therefore, the initial pouring temperature of the concrete should be low, reaching the limit temperature of the building design unit, thus ensuring the quality of the project.

Industrial Chillers manufacturers

TopChiller air-cooled screw chiller adopts a famous four-way valve-like PE, so that solves reversing and system consume great problem exists in other same kinds of products. 2)There is PVC engineering plastic breakwater inside of the evaporator with strong anti-corrosion ability. Chilling water circuitous goes up and down to increase tumble effect, and heat exchangeability. The side of the unit has high/low-pressure meters, a semi-piston type compressor has an oil-pressure gauge. The electrical control box is at one end of the unit, the flange connector for the refrigerant inlet locates the side of the machine. In the subsequent curing or low temperature, the interior of the concrete will be caused by thermal expansion and contraction. Therefore, concrete cooling is required to cool the water before hydration.

Arrived at KIG in March 2016 were these three never used, never installed, 2014 Riedel 2 Ton Air Cooled Chillers. This German made unit is wonderfully engineered with a nice Danfoss/Maneurop Hermetic Reciprocating Compressor, many redundant features, and a high end 1.7 hp Grundfoss Pump. Units were run and tested at 42°F to 70°F fluid temp range at our 13,000 square foot facility prior to shipping. Arrived at KIG in April 2016 was this Nice Advantage Air Cooled Chiller. This 1.5 hp unit has a brand new stainless process pump installed by us, an internal reservoir, and a brazed/plate heat exchanger. Chiller was run and tested extensively, as well as added new insulation. This is an indoor chiller, designed to be in an indoor warehouse/facility environment. Please see the videos posted of its sister unit recently shipped out. Arriving November 2020 is this nice PRM 15 ton air cooled industrial chiller. These are good basic INDOOR industrial closed loop chillers for process applications in the 42°F to 77°F temperature range.

Motivair's ChilledDoor Rack Cooling System is an active rear door heat exchanger capable of removing server densities up to 75kW per rack and 100% heat removal. Motivair Pump Stations are designed, engineered, and manufactured to move fluids in industrial, institutional, and commercial markets. Expansion tank internal on chiller is included if you choose to run a pressurized loop. Units were professionally de-installed, and have glycol in them now. The nominal design parameters are 72 GPM flow, 60F inlet temp and 50F outlet temp. These are "Compresserized Systems" with two compressors within main unit.

The World Bank puts the number of people living with absolute water scarcity at 2bn, a number that could hit the 4.6bn mark within the next 65 years. The water energy nexus has been a regular subject in recent years. Power plants that feed most nations consume a lot of water, either directly or indirectly. When it comes to the feasibility study of a cooling plant, the debate of consuming water or not is very important. Depending on the results of this study, water-cooled or air-cooled chillers will be selected. We offer factory-run testing for all chillers prior to shipment as a standard option every day. Daikin is devoted to overcoming the evolving challenges of air while creating better, more sustainable outcomes for customers and communities.

Any production of excess heat with an air-cooled chiller can actually be beneficial during the cold winter months when the heat could be used to warm the plant and reduce your monthly energy bills. The internal pressure relief valve allows you to limit the maximum fluid pressure to meet the application requirements. Provides analog and digital communication for remote operation, monitoring and data logging. Includes a remote sensor port which allows for remote temperature control of an application when used with a remote sensor . This frees crucial backup power for other mission critical operations while maintaining sensitive climate controlled areas. In most cases the chiller motor is the largest draw on electricity in the entire building. Single speed drives are on or off and cannot adjust for the difference in load the system is running under.

Portable Air has one of the largest air-cooled chiller fleets in the industry. Our vast selection of portable, trailer-mounted air-cooled chiller units is guaranteed to increase your productivity resulting in less downtime for your project. Air-Cooled Chillers from Budzar Industries are engineered, designed and manufactured to meet your exact requirements and in addition, air-cooled chillers tend to be easy to install and require little maintenance. These conservatively calculated energy savings can be much higher because most chillers are selected based on the peak usage time of the year which means the chiller is oversized for the average usage. The condenser is a configuration of horizontal pipes through which hot refrigerant runs. The compressor provides the driving force for moving the refrigerant around the system. Three of them use positive displacement to create pressure, and the fourth creates pressure with centrifugal force. Multi Temp Chillers require a pump to move water through the heat exchanger at all times.

If you are having heating and air installation in Loganville GA, this type of environmental temperature maintenance is the most common in offices, homes, and retail outlets. Optimization of the overall chiller plant must be performed holistically. Various adjustments focusing on optimal chilled water set points, chiller sequencing and load balancing, peak demand management, cooling tower water management, etc. can only be performed with operational data. IoT has found practical application in HVAC to facilitate true optimization. Thermal Care is a leading manufacturer of water chillers, process cooling equipment and systems for applications worldwide. The cooling capacity of our premium air cooled screw chillers ranges from 30 Ton to 550 Ton and their operating sound levels are very low in all conditions. If your air cooled screw chiller gets out of order, it might result in a critical decrease in cooling capacity and even economic damages. By employing a semi-hermetic dual screw compressor, TopChiller® air cooled screw chillers are energy-efficient and able to regulate energy performance levels from 0% to 100% for maximum electricity savings. The air cooled screw chiller has protections of high/low pressure, anti-freeze, oil temperature, overload, phase sequence, and water lacking to ensure unit run safety.

If you require unlimited cooling water for your industrial application, a natural draft cooling tower may be the right choice for you. Since mechanical fans don’t need to be used in this type of cooling tower, the expenses for operating the cooling tower are lower than what’s necessary for a mechanical draft cooling tower. If you require a system that will effectively cool your food processing unit or power plant, the two main types of systems that can be used for numerous cooling purposes include a chiller and a cooling tower. While both of these systems are designed to remove any heat from a liquid before it’s used as a coolant, there are distinct differences between the two systems that you should be fully aware of. Arrived at KIG in October 2014 was this immaculate and well maintained Trane CGAM series 90 ton Air Cooled Chiller. Unit has less than 9500 total run hours, and see the low hours per compressor below.

Discover how to cut energy costs with free cooling chillers and what aspects should be considered when selecting a free cooling system. Lightstream family of air-cooled chillers running on refrigerant R515b represents the next advance in eco-friendly cooling technology while contributing to performance improvement. Highest reliability of our chillers achieved by intelligent engineering and assured through the use of time-proven components, maximum manufacturing quality, and thorough equipment testing. This post covers three angles namely installation, maintenance and operating cost. If noise is a primary concern, then water-cooled chillers are the way to go. Noisy HVAC machines can be an annoyance, especially in buildings occupied by doctor’s offices, call centers, or other business offices. They are also popular where there isn’t ample air recirculation. Any obstructions adversely affect the performance of air-cooled chillers.

Our portable air-cooled chillers are great for one-time events or permanent infrastructure. They are compact and highly efficient, as well as easy to install and remove. This makes them ideal for supplemental, temporary or emergency applications. High efficiency and low noise are the hallmarks of all our air-cooled chillers. Our robust portfolio features a wide operating map – so you can find the just-right solution for your building. We offer an array of tonnage sizes, efficiencies and performance features to meet your requirements. Whether you need a classic chiller with dependable performance or an environmentally conscious chiller with next-generation refrigerant, there’s a Trane model for you.

This is a space where the refrigerant exchanges the heat and finishes the transfer. Air cooled chillers are also used to cool high-heat specialized items such as MRI machines and laser machines, in hospitals, hotels, big buildings, campuses, etc. Each air-cooled chiller manufactured by TopChiller is fully refrigerant charged with movable wheels, water pump, and inlet & outlet piping. Compact design and easy installation, Our air-cooled chiller features a compact design, easy installation/operation with low cost/labor to do regular maintenance. The high efficiency and durable air-cooled type condenser using the finned copper tube with aluminum and big air volume cooling fan. The Surplus Group’s comprehensive Used Chiller Proving Process addresses all aspects of a used air cooled chiller’s mechanical, operational, and physical condition, culminating in a live-load proving run. Additional features include emergency alarms, hot gas bypass, city water switchover, and casters.

The better maintained your chiller is the less energy it uses, and that saves you money on utilities. As the chiller and HVAC system is one of the largest draws of electricity in many commercial, industrial, and medical facilities it is important to inspect, maintain, and repair chillers. Regular inspection and chiller maintenance will help save money and make the system last longer. Chillers function on the principle of condensing refrigerant to cool. If moisture or air leaks into the system it introduces non-condensable elements into the system that rob it of efficiency. The percentage can be as high as 7% below the rated performance of the chiller system you have.

Leave a Reply

Your email address will not be published. Required fields are marked *